We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure no-reply@cambridge.org
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
In radiotherapy, electron beam irradiation is an effective modality for superficial tumours. Electron beams have good coverage of tumours which involve the skin, however there is an issue about electron scattering and tissue heterogeneity. This subsequently demands dosimetric analysis of electron beam behaviour, particularly in the treatment of lesions on the scalp requiring the application of treatment to scalp curvatures. There are various methods which are used to treat scalp malignancies including photons and electrons, but, the later needs precise dosimetry before each session of treatment. The purpose of the study was to undertake a detailed analysis of the dosimetry of electron beams when applied to the curved surface of the scalp using Gafchromic® EBT2 films.
Methods and materials
A rando phantom and Gafchromic® EBT2 films were used for dosimetric analysis. A gafchromic calibration curve was plotted and an in-treatment beam dosimetric analysis was carried out using dosimetry films placed on the scalp. Electron behaviour was assessed by introducing five electron fields in particular curvature regions of scalp.
Result
There was an acceptable dose range through all five fields and hotspots occurred in the curved borders. In our study, skin doses and doses at the field junctions, with no gaps, were between 78–97% and 80–97%, respectively.
Conclusions
Electron beams are a good modality for treating one flat field, but in the special topography of the scalp, whole scalp treatment requires precise field matching and dosimetry. In undertaking this detailed dosimetric analysis using a rando phantom and Gafchromic® EBT2 films, it is concluded that this method requires further detailed analysis before using in clinics.