We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure no-reply@cambridge.org
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
Patients having a course of radiotherapy (RT) must be appropriately immobilised for stability and accuracy. Having opened a new cancer service in June 2009 and commenced treating lower gastrointestinal cancers in 2010, a prone belly board device (BBD) was introduced as the standard radiotherapy immobilisation. A training package was created to aid clinical skills retention of therapeutic radiographers and manage setup quality. Setup reproducibility using the BBD was retrospectively assessed with electronic portal image (EPI) verified geometric displacements as the main outcome measure both before and after the introduction of training.
Method
Twenty retrospective Pinnacle computed tomography-planned patients and their geometric displacements on treatment were evaluated between 2010 and 2011—ten prior to (Patient Group A) and ten following training (Patient Group B). The only inclusion criterion was that patients were immobilised for RT on the Medtec ContouraTM carbon fibre BBD. Patients were prone and were treated to 45–50·4 Gy in 25–28 fractions on a 6–10 MV LinAc equipped with EPI. Reproducibility was assessed by comparing geometric measurement of the bony pelvis on the Pinnacle digitally reconstructed radiograph (DRR) with an EPI captured at day 0, 1, 2 and weekly during treatment for each patient. Systematic and random errors were analysed with respect to the average geometric displacement with standard deviation per patient between the Pinnacle DRR and the EPI.
Results
The age range was 41–77 years and there were 15 male and five female patients with diagnosed rectal cancers (T3–T4, N0–N2, M0). Three hundred and seventy one images were analysed. An improvement in population systematic and random error was most notable in the superior–inferior direction (Patient Group A Σpop = 3·1 mm, σpop = 3·6 mm to Patient Group B Σpop = 2·0 mm, σpop = 2·3 mm, respectively).
Discussion/Conclusion
There is evidence that the use of the BBD is more reproducible when accompanied by a task-specific training package. Based on the results of this study, further work will be carried out on training standardisation for patient positioning with a BBD for reducing systematic and random geometric displacements.