We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure no-reply@cambridge.org
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
The Focused Abdominal Sonography in Trauma (FAST) scan is used to detect free fluid in the peritoneal cavity, or pericardium, to quickly assess for injuries needing immediate surgical intervention. Mass-casualty incidents (MCIs) are settings where paramedics must make triage decisions in minutes. The Simple Triage and Rapid Transport (START) system is used to prioritize transport. The FAST scan can be added to the triage of critical patients, and may aid in triage.
Methods
This was a single-blinded, randomized control trial. Ten paramedics with field experience were trained with an ultrasound machine in the performance of the FAST scan. Two weeks were allowed to pass before testing to simulate the time between training of standard procedures and their implementation. On test day, five peritoneal dialysis patients with instilled dialysis fluid and five matched control patients were placed in a room in a random order where the paramedics performed FAST scans on each patient. The paramedics were assessed by declaring positive or negative for each evaluation, as well as being timed for the total exercise.
Results
Of the ninety tests (one paramedic dropped out due to family emergency), the paramedics had a mean accuracy of 60% and median of 62% (range 40%-80%). There was a statistically significant higher false-positive rate of 59% than false-negative rate of 41% (P < .01). Sensitivity was 67% with a specificity of 56%. Average time taken was 1,218 seconds (121.8 seconds per patient) with a range of 735-1,701 seconds and a median of 1,108 seconds.
Conclusion
In this simulation study, paramedics had difficulty performing FAST scans with a high degree of accuracy. However, they were more apt to call a patient positive, limiting the likelihood for false-negative triage.
WestB, CusserJA, EtengoffS, LandsgaardH, LaBondV. The Use of FAST Scan by Paramedics in Mass-casualty Incidents: A Simulation Study. Prehosp Disaster Med. 2014;29(6):1-4.