Published online by Cambridge University Press: 09 December 2020
The objective of this study has been to identify monitor unit (MU) and treatment time variations, volume coverage dissimilarity among 3D conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) treatment plans for head and neck cancer (HNC) based on literature review.
A number of HNC cases were studied with the investigation of conformity and homogeneity index.
When high-dose modulation was required around small organs at risk (OARs), a clinically acceptable IMRT plan was achieved as VMAT usually required longer dose optimisation time. The greatest benefit of VMAT has been rapid treatment delivery allowing improved patient comfort, reduced intra-fraction motion and increased patient throughput. In some papers, 3D-CRT was shown not to meet well the requirements on parotid glands. One paper showed that cerebellum dose was lower for 3D-CRT than IMRT. However, it was found in other papers that OAR sparing with 3D-CRT was reasonable but in complex cases not enough.
IMRT usually consists of several treatment fields with different directions, hundreds of beam lets with modulated intensity, an advantage over 3D-CRT, whereas VMAT has advantage over IMRT due to rotating beam utilisation. VMAT has lower total MU and treatment times than IMRT and 3D-CRT, while maintaining similar dosimetric endpoints.
To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
Find out more about the Kindle Personal Document Service.
To save this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you used this feature, you will be asked to authorise Cambridge Core to connect with your Dropbox account. Find out more about saving content to Dropbox.
To save this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you used this feature, you will be asked to authorise Cambridge Core to connect with your Google Drive account. Find out more about saving content to Google Drive.