Published online by Cambridge University Press: 01 August 2022
This study aimed to evaluate the efficacy and safety of high-frequency oscillation ventilation combined with intermittent mandatory ventilation in infants with acute respiratory distress syndrome after congenital heart surgery.
We retrospectively analysed the clinical data of 32 infants who were ventilated due to acute respiratory distress syndrome after congenital heart surgery between January, 2020 and January, 2022. We adopted high-frequency oscillation ventilation combined with intermittent mandatory ventilation as the rescue ventilation mode for infants who were failing conventional mechanical ventilation.
After rescue high-frequency oscillation ventilation combined with intermittent mandatory ventilation, the dynamic compliance (Cdyn), PaO2 and PaO2/FiO2 ratio of the infants improved compared with conventional mechanical ventilation (p < 0.05). Moreover, high-frequency oscillation ventilation combined with intermittent mandatory ventilation resulted in a significant decrease in arterial-alveolar oxygen difference (AaDO2), FiO2, and oxygenation index (p < 0.05). No significant effect on haemodynamic parameters was observed. Moreover, no serious complications occurred in the two groups.
Rescue high-frequency oscillation ventilation combined with intermittent mandatory ventilation significantly improved oxygenation in infants who failed conventional mechanical ventilation for acute respiratory distress syndrome after congenital heart surgery. Thus, this strategy is considered safe and feasible. However, further studies must be conducted to confirm the efficacy and safety of high-frequency oscillation ventilation combined with intermittent mandatory ventilation as a rescue perioperative respiratory support strategy for CHD.
These authors share the corresponding authorship.
To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
Find out more about the Kindle Personal Document Service.
To save this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you used this feature, you will be asked to authorise Cambridge Core to connect with your Dropbox account. Find out more about saving content to Dropbox.
To save this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you used this feature, you will be asked to authorise Cambridge Core to connect with your Google Drive account. Find out more about saving content to Google Drive.