We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure no-reply@cambridge.org
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
At present, the exclusion for percutaneous pulmonary valve implantation for free pulmonary regurgitation after tetralogy of Fallot repair includes an unfavourably large right ventricular outflow tract.
Objective
To report feasibility and early experience with a recently developed transcatheter heart valve, Venus P-valveTM, implanted in six patients with severe pulmonary regurgitation with large right ventricular outflow tracts.
Patients
There were two female patients and four male patients. The median age of the patients was 18.5 years, and the mean body weight was 53.8 kg. All the patients were in NYHA class II and had severe pulmonary regurgitation after previous transannular patch repair of tetralogy of Fallot. The median time after the last surgical operation was 13.5 years.
Results
The Venus P-valveTM was successfully implanted in all the patients with implanted valve diameters ranging from 24 to 32 mm. The mean fluoroscopy time was 29.8 minutes. None of the patients had significant outflow tract gradient or pulmonary regurgitation immediately after valve implantation. Only one patient had unexpected mild proximal valve migration to the right ventricular body during withdrawal of the delivery system. It caused mild paravalvar leak and significant tricuspid regurgitation. At 6 months follow-up, the median of right ventricular end-diastolic volume indices decreased from 146 to 108 ml/m2 (p-value=0.046). The Doppler systolic peak gradient across the valve ranged from 4 to 40 mmHg, and there was no evidence of stent fracture on fluoroscopy or structural valve failure.
Conclusion
The Venus P-valveTM can be implanted successfully and effectively in patients with severe pulmonary regurgitation and a large right ventricular outflow tract. The early results with this valve are encouraging.