Hostname: page-component-857557d7f7-zv5th Total loading time: 0 Render date: 2025-12-02T16:56:19.715Z Has data issue: false hasContentIssue false

Percutaneous closure of a left atrio-ventricular valve paravalvular leak with the Occlutech Paravalvular Leak Device in a 5-year-old child

Published online by Cambridge University Press:  01 December 2025

Natalie Soszyn*
Affiliation:
Division of Cardiology, Department of Pediatrics, Heart Institute, Children’s Hospital Colorado, University of Colorado Denver | Anschutz Medical Campus, Aurora, CO, USA
Jenny E. Zablah
Affiliation:
Division of Cardiology, Department of Pediatrics, Heart Institute, Children’s Hospital Colorado, University of Colorado Denver | Anschutz Medical Campus, Aurora, CO, USA
Gareth J. Morgan
Affiliation:
Division of Cardiology, Department of Pediatrics, Heart Institute, Children’s Hospital Colorado, University of Colorado Denver | Anschutz Medical Campus, Aurora, CO, USA
*
Corresponding author: Natalie Soszyn; Email: nsoszyn@hotmail.com

Abstract

Since 2014, transcatheter paravalvular leak closure with the Occlutech Paravalvular Leak Device has been successfully accomplished in adults with high technical success. We describe the first successful use of the Occlutech Paravalvular Leak Device in the left atrio-ventricular valve in the United States in a 5-year-old child with a history of previously repaired atrio-ventricular septal defect.

Information

Type
Case Report
Copyright
© The Author(s), 2025. Published by Cambridge University Press

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Article purchase

Temporarily unavailable

References

Calvert, PA, Northridge, DB, Malik, IS, et al. Percutaneous device closure of paravalvular leak: combined experience from the United Kingdom and Ireland. Circulation 2016; 134: 934944.CrossRefGoogle Scholar
García, E, Arzamendi, D, Jimenez-Quevedo, P, et al. Outcomes and predictors of success and complications for paravalvular leak closure: an analysis of the spanisH real-wOrld paravalvular LEaks closure (HOLE) registry. EuroIntervention 2017; 12: 1962–8.CrossRefGoogle ScholarPubMed
Bedair, R, Morgan, GJ, Bapat, V, et al. Early experience with the Occlutech PLD occluder for mitral paravalvar leak closure through a hybrid transapical approach. EuroIntervention 2016; 12: e1420e1427.CrossRefGoogle ScholarPubMed
Onorato, EM, Alamanni, F, Muratori, M, et al. Efficacy and long-term outcomes of patients treated with the Occlutech paravalvular leak device for significant paravalvular regurgitation. J Clin Med 2022; 11: 11.CrossRefGoogle ScholarPubMed
Goktekin, O, Vatankulu, MA, Ozhan, H, et al. Early experience of percutaneous paravalvular leak closure using a novel Occlutech occluder. EuroIntervention 2016; 11: 11951200.CrossRefGoogle ScholarPubMed
Hourihan, M, Perry, SB, Mandell, VS, Keane, JF, Rome, JJ, Bittl, JA, et al. Transcatheter umbrella closure of valvular and paravalvular leaks. J Am Coll Cardioi 1992; 20: 13711377.CrossRefGoogle ScholarPubMed
Jiménez-Valverde, AS, Escutia-Cuevas, HH, Aceves-Millán, R, Fuentes-Espinoza, PM, Pérez-Siller, G, Espinoza-Rueda, MA. Percutaneous closure of aortic and mitral paravalvular leak with the OcclutechTM PL device - report of the first cases in Mexico. Arch Cardiol Mex 2019; 89: 8891.Google Scholar
Onorato, EM, Muratori, M, Smolka, G, Malczewska, M, Zorinas, A, Zakarkaite, D, et al. Midterm procedural and clinical outcomes of percutaneous paravalvular leak closure with the occlutech paravalvular leak device. EuroIntervention 2020; 15: 12511259.CrossRefGoogle ScholarPubMed
Onorato, EM, Alamanni, F, Muratori, M, et al. Clinical medicine safety, efficacy and long-term outcomes of patients treated with the Occlutech paravalvular leak device for significant paravalvular regurgitation. J Clin Med 2022; 11: 1978.CrossRefGoogle ScholarPubMed